Novovac Set

90050-90135 [/salt_icon_text]

Novovac Set
[salt_icon_text css=”.vc_custom_1558345651633{padding-top: 5px !important;padding-right: 20px !important;padding-bottom: 5px !important;padding-left: 20px !important;background-color: #efefef !important;}”]

Closed Wound Suction Unit with Spring

[/salt_icon_text][salt_icon_text]

  • Closed wound drainage system with graduated Transparent Spring bellow, suitable for drainage under negative pressure post operatively with the options to operate one or two catheters simultaneously
  • Sizes of Bellow Chamber : 200 & 400ml

[/salt_icon_text]

[salt_icon_text align=”center” css=”.vc_custom_1560943122111{padding-top: 5px !important;padding-right: 20px !important;padding-bottom: 5px !important;padding-left: 20px !important;background-color: #efefef !important;}”]

Polyvac Set

90070-90199 [/salt_icon_text]

Polyvac Set
[salt_icon_text css=”.vc_custom_1558345758295{padding-top: 5px !important;padding-right: 20px !important;padding-bottom: 5px !important;padding-left: 20px !important;background-color: #efefef !important;}”]

Closed Wound Suction Unit

[/salt_icon_text][salt_icon_text]

  •  Suitable for close wound drainage under negative pressure post operatively with the option to operate one or two catheters simultaneously
  •  Graduated Bellow Chamber
  • Sizes of Bellow Chamber : 600 & 800ml

[/salt_icon_text]

[salt_icon_text align=”center” css=”.vc_custom_1564841313477{padding-top: 5px !important;padding-right: 20px !important;padding-bottom: 5px !important;padding-left: 20px !important;background-color: #efefef !important;}”]

Neovac Set

90650-90651 [/salt_icon_text]

Neovac Set
[salt_icon_text css=”.vc_custom_1564841339999{padding-top: 5px !important;padding-right: 20px !important;padding-bottom: 5px !important;padding-left: 20px !important;background-color: #efefef !important;}”]

Closed Wound Suction Unit

[/salt_icon_text][salt_icon_text]

  • Suitable for minor surgery and plastic surgery
  • Unit consists of:
    1. Bellow container capacity: 50ml
    2. Curved trocar with redon catheter
  • Sizes : 6 FG & 8 FG

[/salt_icon_text]

[salt_icon_text]

Common features

[/salt_icon_text][salt_icon_text]

  • Unit consists of:
    • 1. Bellow unit connector
    • 2. Connecting tube with clamp and “Y” connector
    • 3. Curved trocar with catheter
    • 4. Perforated DEHP Free Redon drain catheter
  •  Sizes : 10, 12, 14, 16 & 18FG

[/salt_icon_text]

[salt_icon_text align=”center” css=”.vc_custom_1560943188031{padding-top: 5px !important;padding-right: 20px !important;padding-bottom: 5px !important;padding-left: 20px !important;background-color: #efefef !important;}”]

Redon Drain

90060-90186 [/salt_icon_text]

Redon Drain
Redon Drain-2
[salt_icon_text]

  •  Provided with radio-opaque line and smooth eyes
  •  Cross perforated length of tube: 14cm
  •  Markings on the tube at 19 cm from the distal tip
  •  Soft, frosted & kink resistant PVC tubing
  •  Length: 50, 70, 120 & 170 cm
  •  Sizes: 8, 10, 12, 14, 16 & 18 FG
  •   DEHP Free

[/salt_icon_text]

[salt_icon_text align=”center”]

Our Blogs

[/salt_icon_text][salt_icon_text]

Polymed Receives ‘India Medical Devices Company of the Year’ Award
The Award, presented by the Government of India, underscores Polymed’s continued leadership position in Medical devices sector Polymed focuses on tapping huge potential in Domestic ...
Fundamentals, Lets Go Back to Basics
Polymed announces the Academic Initiatives in collaboration with Infusion Nurses Society, India on nursing practices for good nursing care. As the work of nursing becomes ...
Guarded fistula needle reduces Needle Stick Injuries in Haemodialysis Units
Needle Stick Injuries are injuries caused by accidental penetration of the skin by an injection needle. Globally, NSI’s are the most common source of occupational ...
[/salt_icon_text][salt_buttons round_type=”rounded” bg_color_btn=”primary-btn”]
[salt_icon_text align=”center”]

Quick Contact

[/salt_icon_text]

[salt_icon_text]

EMAIL

info@polymedicure.com[/salt_icon_text]

[salt_icon_text]

Call Us

+91 9999 999 999[/salt_icon_text]

[salt_icon_text]

CAREER

ca@polymedicure.com[/salt_icon_text]